Medium - WWTP 40 - 150 /People Equivalent/

The wastewater treatment facilities ВТ 50 – ВТ 150 are designed to treat medium sources of wastewater such as small settlements, hamlets, hotels placed out of towns, camping sites, motels, petrol stations and some small industrial enterprises.

Wastewater treatmant plants - BioTeh
Wastewater treatmant plants - BioTeh
Wastewater treatmant plants - BioTeh
Wastewater treatmant plants - BioTeh
Wastewater Treatment Plants - Bioteh
Wastewater Treatment Plants - Bioteh
Wastewater Treatment Plants - Bioteh

The biological wastewater treatment plant is built up by polymer materials and is separated into parts according to the relevant technological processes.

Technical Parameters

WWTP BT 50 BT 60 BT 80 BT 100 BT 150
Capacity (P.E.) 40 - 50 47 - 60 60 - 80 75 - 100 90 - 150
Sewage volume m3/day 7.5 - 9.0 9.0 - 12.0 12.0 - 13.6 13.6 - 17.0 17.0 - 24.8
Input power W 350 400 500 500 650
Dimensions m 4.0 х 2.0 4.5 х 2.0 4.0 х 2.5 4.0 х 3.0 4.0 х 3.5
Height m 2.50 2.50 2.50 3.00 3.00

Impurities reduction in the relevant technological compartments is as follows:

  • At the bar rack – 20% reduction of the coarse materials;
  • In the anoxic compartment – 20 % reduction of BOD5 and 85 % reduction of nitrogen (anaerobic reduction of the nitrates, transferred there from the aerobic compartment);
  • In the aerobic compartment – 95 % reduction of BOD5, 95 % reduction of ammonia, 75 % reduction of phosphorus (by chemical precipitation) if required and suspended solids reduction down to 15 mg/l;
  • In the disinfection chamber – 99,9 % reduction of the bacterial impurity (in respect to Esherihia Coli).

EFFECT OF TREATMENT WITH TECHNOLOGY "BIOTEH " BT - 98%